Pneumatic pulsator controllers

INDUSTRIAL AUTOMATION

Pneumatic pulsator controllers:

Pneumatic pulsator controller SOP 08 A

SOP 08 A

 

The pneumatic pulsator controller SOP 08 A constantly checks the correct operation of the valve

UP TO 8 VALVES
The number of connected valves can be set in the control panel from 1 to 8

The controller is mounted in a small plastic housing with IP65 protection. It can be powered directly by 230V AC mains voltage. The controller can be installed both on a 35 mm DIN rail and on a construction. The system works in cyclical mode. In cyclic mode, all connected valves are switched on successively for the duration of the pulse. After the pulse of each valve, the time between pulses is counted down. After the last valve pulse, the system counts down the time between cycles and starts operation from the beginning – from the first valve. The controller constantly checks the correct operation of the valves and in the event of a fault an alarm is generated. The number of connected valves can be set in the control panel from 1 to 8. The controller is equipped with an operator panel with a 2 x 8 character LCD screen mounted on the top cover of the controller, enabling parameter setting and system operation control. The controller is placed in a dustproof IP65 housing with a safety flap adapted for closing with a padlock.

System Data:

  1. Digital outputs (24V DC / 1.6A) Valve control ……… 8 pcs.
  2. Digital input (start / stop) of regeneration ……… 2 pcs.
  3. Relay output (normally open contact) 2A / 230V AC (alarm signal) ……… 1 pcs.
  4. Valve supply voltage ……… 24V DC
  5. Maximum power consumed by the valve ……… 20 W
  6. Pulse time range [Tp] ……… 1 – 10 sec.
  7. Range of intervals between pulses [Tbp] ……… 15 – 1250 sec.
  8. Pause range between cycles [Tbc] ……… 0 – 1440 min.
  9. Controller supply voltage ……… 230 V AC, 50 Hz, 50 W
  10. Dimensions (width-height-depth) ……… 166x161x121 mm

Pneumatic pulsator controller SOP 08 A (85-264V AC)

SOP 08 A (85-264V AC)

 

The pneumatic pulsator controller SOP 08 A (85-264V AC) constantly checks the correct operation of the valve

UP TO 8 VALVES
The number of connected valves can be set in the control panel from 1 to 8

The controller is mounted in a small plastic housing with IP65 protection. It can be powered directly by 85-264V AC mains voltage. The controller can be installed both on a 35 mm DIN rail and on a construction. The system works in cyclical mode. In cyclic mode, all connected valves are switched on successively for the duration of the pulse. After the pulse of each valve, the time between pulses is counted down. After the last valve pulse, the system counts down the time between cycles and starts operation from the beginning – from the first valve. The controller constantly checks the correct operation of the valves and in the event of a fault an alarm is generated. The number of connected valves can be set in the control panel from 1 to 8. The controller is equipped with an operator panel with a 2 x 8 character LCD screen mounted on the top cover of the controller, enabling parameter setting and system operation control. The controller is placed in a dustproof IP65 housing with a safety flap adapted for closing with a padlock.

System Data:

  1. Digital outputs (24V DC / 1.6A) Valve control ……… 8 pcs.
  2. Digital input (start / stop) of regeneration ……… 2 pcs.
  3. Relay output (normally open contact) 2A / 230V AC (alarm signal) ……… 1 pcs.
  4. Valve supply voltage ……… 24V DC
  5. Maximum power consumed by the valve ……… 20 W
  6. Pulse time range [Tp] ……… 1 – 10 sec.
  7. Range of intervals between pulses [Tbp] ……… 15 – 1250 sec.
  8. Pause range between cycles [Tbc] ……… 0 – 1440 min.
  9. Controller supply voltage ……… 85-264V AC, 50 Hz, 50 W or 24V DC
  10. Dimensions (width-height-depth) ……… 166x161x121 mm

Pneumatic pulsator controller SOP 12 A

SOP 12 A

The pneumatic pulsator controller SOP 12 A constantly checks the correct operation of the valve

UP TO 12 VALVES
The number of connected valves can be set in the control panel from 1 to 12

The SOP 12 A controller is a microprocessor-based electronic system. The controller is mounted in a small plastic housing. It can be powered directly by 230V AC mains voltage. The controller must be installed on a 35 mm DIN rail. The system works in cyclical mode. In cyclic mode, all connected valves are switched on successively for the duration of the pulse. After the pulse of each valve, the time between pulses is counted down. After the last valve pulse, the system counts down the time between cycles and starts operation from the beginning – from the first valve. The controller constantly checks the correct operation of the valves and in the event of a fault an alarm is generated. The controller is equipped with an operator panel with a 2 x 8 character LCD screen mounted on the top cover of the controller, enabling parameter setting and system operation control.

System Data:

  1. Digital outputs (24V DC / 1.6A) Valve control ……… 12 pcs.
  2. Digital inputs (1: start / stop, 2: for example, compressed air control) ……… 2 pcs.
  3. Relay output (normally open contact) 2A / 230V AC (alarm signal) ……… 1 pcs.
  4. Valve supply voltage ……… 24V DC
  5. Maximum power consumed by the valve ……… 20 W
  6. Pulse time range [Tp] ……… 1 – 10 sec.
  7. Range of intervals between pulses [Tbp] ……… 15 – 1250 sec.
  8. Pause range between cycles [Tbc] ……… 0 – 1440 min.
  9. Controller supply voltage ……… 230 V AC, 50 Hz, 50 W
  10. Dimensions (width-height-depth) ……… 158x90x57 mm

Pneumatic pulsator controller SOP 08 V16 A (85-264V AC)

SOP 08 V16 A (85-264V AC)

The pneumatic pulsator controller SOP 08 V16 A (85-264V AC) constantly checks the correct operation of the valve

UP TO 16 VALVES
The number of connected valves can be set in the control panel from 1 to 16

The controller is mounted in a small plastic housing with IP65 protection. It can be powered directly by 85-264V AC mains voltage. The controller can be installed both on a 35 mm DIN rail and on a construction. The system works in cyclical mode. In cyclic mode, all connected valves are switched on successively for the duration of the pulse. After the pulse of each valve, the time between pulses is counted down. After the last valve pulse, the system counts down the time between cycles and starts operation from the beginning – from the first valve. The controller constantly checks the correct operation of the valves and in the event of a fault an alarm is generated. The number of connected valves can be set in the control panel from 1 to 16. The controller is equipped with an operator panel with a 2 x 8 character LCD screen mounted on the top cover of the controller, enabling parameter setting and system operation control. The controller is placed in a dustproof IP65 housing with a safety flap adapted for closing with a padlock.

System Data:

  1. Digital outputs (24V DC / 1.6A) Valve control ……… 16 pcs.
  2. Digital input (start / stop) of regeneration ……… 2 pcs.
  3. Relay output (normally open contact) 2A / 230V AC (alarm signal) ……… 1 pcs.
  4. Valve supply voltage ……… 24V DC
  5. Maximum power consumed by the valve ……… 20 W
  6. Pulse time range [Tp] ……… 1 – 10 sec.
  7. Range of intervals between pulses [Tbp] ……… 15 – 1250 sec.
  8. Pause range between cycles [Tbc] ……… 0 – 1440 min.
  9. Controller supply voltage ……… 85-264V AC, 50 Hz, 50 W or 24V DC
  10. Dimensions (width-height-depth) ……… 166x161x121 mm

Pneumatic pulsator controller SOP 1NV A

SOP 1NV A

The pneumatic pulsator controller SOP 1NV A constantly checks the correct operation of the valve

UP TO 48 VALVES 

The controller is mounted in a small plastic housing MODULBOX XT. The controller must be installed on a 35 mm DIN rail. The system works in cyclic  mode. In cyclic mode, all connected valves are switched on successively for the duration of the pulse. After the pulse of each valve, the time between pulses is counted down. After the last valve pulse, the system counts down the time between cycles and starts operation from the beginning – from the first valve. The controller constantly checks the correct operation of the valves, and in the event of a fault an alarm is generated. The controller is equipped with an operator panel with a 2 x 8 character LCD screen mounted on the top cover of the controller or an external operator panel PST 1N IP67 designed for mounting on the door of the control cabinet, enabling parameter setting and operation of the installation control system.

System Data:

  1. Digital outputs (24V DC / 1.6A) Valve control ……… 12 pcs.
  2. Digital outputs (24VDC / 1.6A) Section control ……… 4 pcs.
  3. Digital inputs (1: start / stop, 2: for example, compressed air control) ……… 3 pcs.
  4. Relay output (normally open contact) 2A / 230V AC (alarm signal) ……… 1 pcs.
  5. Analogue inputs ……… 1 pcs.
  6. Valve supply voltage ……… 24V DC
  7. Maximum power consumed by the valve ……… 20 W
  8. Pulse time range [Tp] ……… 1 – 10 sec.
  9. Range of intervals between pulses [Tbp] ……… 15 – 1250 sec.
  10. Pause range between cycles [Tbc] ……… 0 – 1440 min.
  11. Controller supply voltage ……… 85-264V AC, 50 Hz, 50 W or 24V DC
  12. Dimensions (width-height-depth) ……… 158x90x57 mm

Pneumatic pulsator controller SOP 17 A

SOP 17 A

The pneumatic pulsator controller SOP 17 constantly checks the correct operation of the valve

UP TO 576 VALVES

The controller is mounted in a small plastic housing MODULBOX XT. The controller must be installed on a 35 mm DIN rail. It can be powered directly by 85-264V AC mains voltage. The system works in cyclic mode. In cyclic mode, all connected valves are switched on successively for the duration of the pulse. After the pulse of each valve, the time between pulses is counted down. After the last valve pulse, the system counts down the time between cycles and starts operation from the beginning – from the first valve. The controller constantly checks the correct operation of the valves, and in the event of a fault an alarm is generated. The controller is equipped with an operator panel with a 2 x 16 character LCD screen mounted on the top cover of the controller or an external operator panel PST 2N IP67 designed for mounting on the door of the control cabinet, enabling parameter setting and operation of the installation control system.

System Data:

  1. Digital outputs (24V DC / 1.6A) Valve control ……… 12 pcs.
  2. Digital outputs (24VDC / 1.6A) Section control ……… 6 pcs.
  3. Digital inputs (1: start / stop, 2: for example, compressed air control) ……… 5 pcs.
  4. Relay output (normally open contact) 2A / 230V AC (alarm signal) ……… 1 pcs.
  5. Analogue inputs ……… 2 pcs.
  6. Valve supply voltage ……… 24V DC
  7. Maximum power consumed by the valve ……… 20 W
  8. Pulse time range [Tp] ……… 1 – 10 sec.
  9. Range of intervals between pulses [Tbp] ……… 15 – 1250 sec.
  10. Pause range between cycles [Tbc] ……… 0 – 1440 min.
  11. Controller supply voltage ……… 85-264V AC, 50 Hz, 50 W or 24V DC
  12. Dimensions (width-height-depth) ……… 218x110x60 mm

Expansion modules for the SOP 17 A controller

  1. SOP17_8DI_8DO module – 8 digital inputs 24V DC / AC and 8 digital outputs 24V DC / 3A
    The SOP17_8DI_8DO module has 8 digital 24V DC inputs with galvanic isolation between the inputs and SOP17 controller (CPU) and 8 digital 24V DC / 3A outputs with galvanic isolation between the SOP17 controller (CPU) and outputs. The digital inputs are galvanically isolated from the digital outputs. You can use up to 6 SOP17_8DI_8DO modules.
  2. Module SOP17_8DI_8DO_230V AC – 8 digital inputs 24V DC / AC and 8 digital outputs 230V AC / 2A
    The SOP17_8DI_8DO_230V AC module has 8 digital 24V DC inputs with galvanic isolation between the inputs and the SOP17 controller (CPU) and 8 digital outputs 230V AC / 2A with galvanic isolation between the SOP17 controller (CPU) and the outputs. The digital inputs are galvanically isolated from the digital outputs. A maximum of 6 SOP17_8DI_8DO_230V AC modules can be used.
  3. SOP17_4AI_1AO module – 4 4-20mA analog inputs and 1 4-20mA analog output
    The SOP17_4AI_1AO module has 4 4-20mA analog inputs with galvanic isolation between the inputs and the SOP17 controller (CPU) and each other between individual inputs, and 1 analog output with galvanic isolation between the SOP17 controller (CPU) and also between the individual analog inputs. So this is full mutual isolation between all entrances and exits. The module requires an external 24V DC power supply to generate individual isolated 24V DC voltages for individual analog inputs. A maximum of 8 SOP17_4AI_1AO modules can be used.